Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Paquete/Caja | Embalaje | Estado del producto | Tipo de sensor | Rango de humedad | Tipo de salida | Salida | Precisión | Tiempo de respuesta | Sensibilidad | Voltaje - Suministro | Tipo de montaje | Temperatura de funcionamiento | Grado | Calificación | Proveedor Dispositivo Paquete |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
A/RH2-1K-NI-ORelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-20K-SP-010Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-10K-E1-SP-010Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-20K-O-BBRelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-50K-SP-05Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 5V | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-0.1CP-DRelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-50K-SP-010Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-100-3W-SP-010Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-1K-3W-O-BBRelative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-100KS-ORelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-1K-2W-O-BBRelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-50K-ORelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-AN-SP-010Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-BALCO-O-4XRelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-10KS-ORelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-CP-SP-05Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 5V | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-10K-E1-ORelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-3K-SP-010Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-AN-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-AN | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |
![]() |
A/RH2-CP-R2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
A/RHx-CP | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current, Analog Voltage | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 1.5°C ~ 60°C | - | - | Module |