Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Paquete/Caja | Embalaje | Estado del producto | Tipo de sensor | Rango de humedad | Tipo de salida | Salida | Precisión | Tiempo de respuesta | Sensibilidad | Voltaje - Suministro | Tipo de montaje | Temperatura de funcionamiento | Grado | Calificación | Proveedor Dispositivo Paquete |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
A/RH2-R-LCD-010Relative Humidity, Room, Humidit |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±2% RH | - | - | 20 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | 0°C ~ 40°C | - | - | - |
![]() |
A/RH2-R-LCD-420Relative Humidity, Room, Humidit |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | - | - | 20 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | 0°C ~ 40°C | - | - | - |
![]() |
A/RH2-TT100-O-4X-1Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 1V ~ 5V | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-TT100-O-4X-4Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-R-LCD-05Relative Humidity, Room, Humidit |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Voltage | 0V ~ 5V | ±2% RH | - | - | 20 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | 0°C ~ 40°C | - | - | - |
![]() |
A/RH3-R-LCD-010-NISTRelative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | Analog Voltage | 0V ~ 10V | ±3% RH | - | - | 20 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | 0°C ~ 40°C | - | - | - |
![]() |
A/RH2-TT1K-O-4X-2Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 2V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-TT1K-O-4X-1Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 1V ~ 5V | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-TTM1K-D-4X-4Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
HG80IHumidistat, Duct, Internal Setpo |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity | 0 ~ 100% RH | SPDT | - | ±4% RH | 120 s | - | - | Chassis Mount | 0°C ~ 60°C | - | - | - |
![]() |
A/RH3-TTM1K-O-4X-4Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH3-TTM100-O-4X-4Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±3% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | Module |
![]() |
A/RH2-TTM1K-R2-4Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM1K-R-4Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM1K-R-2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 2V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM100-R-4Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM1K-R2-2Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 2V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM1K-R2-1Relative Humidity, RH Outputs: 0 |
1 |
|
![]() Tabla de datos |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 1V ~ 5V | ±2% RH | 20 s | - | 18 ~ 28VAC, 12 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM1K-D-BB-2Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Voltage | 2V ~ 10V | ±2% RH | 20 s | - | 18 ~ 28VAC, 18 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |
![]() |
A/RH2-TTM100-D-BB-4Relative Humidity, RH Outputs: 0 |
1 |
|
- |
- | Module | Tape & Box (TB) | Active | Humidity, Temperature | 0 ~ 100% RH | Analog Current | 4mA ~ 20mA | ±2% RH | 20 s | - | 18 ~ 28VAC, 15 ~ 40VDC | Chassis Mount | -40°C ~ 60°C | - | - | - |