Foto | N.º de Parte del Fabricante | Disponibilidad | Cantidad | Hoja de Datos | Serie | Paquete/Caja | Embalaje | Estado del producto | Tipo | Número de salidas | Voltaje: entrada (mín.) | Voltaje: entrada (máx.) | Voltaje - Salida 1 | Voltaje - Salida 2 | Voltaje - Salida 3 | Voltaje - Salida 4 | Corriente - Salida (máx.) | Potencia (vatios) | Voltaje - Aislamiento | Aplicaciones | Características | Temperatura de funcionamiento | Eficiencia | Grado | Calificación | Tipo de montaje | Proveedor Dispositivo Paquete | Funciones de control | Organismo de aprobación | Número estándar |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
0RCY-60U05LDC DC CONVERTER 5V 75W Bel Fuse Inc. |
0 |
|
![]() Tabla de datos |
0RCY-60U | 8-DIP Module, 1/8 Brick | Bulk | Active | Isolated Module | 1 | 18V | 75V | 5V | - | - | - | 15A | 75 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 92.5% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
0RCY-60U120DC DC CONVERTER 12V 84W Bel Fuse Inc. |
0 |
|
![]() Tabla de datos |
0RCY-60U | 8-DIP Module, 1/8 Brick | Bulk | Active | Isolated Module | 1 | 18V | 75V | 12V | - | - | - | 7A | 84 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 92% | - | - | Through Hole | - | Enable, Active High | - | - |
![]() |
0RCY-80RV8LDC DC CONVERTER 1.8V 54W Bel Fuse Inc. |
0 |
|
![]() Tabla de datos |
0RCY-80R | 8-DIP Module, 1/8 Brick | Bulk | Active | Isolated Module | 1 | 18V | 36V | 1.8V | - | - | - | 30A | 54 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, SCP, UVLO | -40°C ~ 85°C | 90% | - | - | Through Hole | - | Enable, Active Low | - | - |
![]() |
0RQB-D0T120DC DC CONVERTER 12V 216W Bel Fuse Inc. |
0 |
|
![]() Tabla de datos |
0RQB-D0T | 8-DIP Module, 1/4 Brick | Bulk | Active | Isolated Module | 1 | 36V | 75V | 12V | - | - | - | 18A | 216 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C | 92.5% | - | - | Through Hole | - | Enable, Active High | - | - |
![]() |
0RSB-50T03ADC DC CONVERTER 3.3V 50W Bel Fuse Inc. |
0 |
|
![]() Tabla de datos |
xRSB-50T | Sixteenth Brick | Bulk | Active | Isolated Module | 1 | 36V | 75V | 3.3V | - | - | - | 15A | 50 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C (With Derating) | 89% | - | - | Through Hole | Sixteenth Brick | - | - | - |
![]() |
0RXC-75TD30DC DC CONVERTER 3.3V 1.8V 77W Bel Fuse Inc. |
0 |
|
- |
0RXC-75TD3x | Quarter Brick | Bulk | Active | Isolated Module | 2 | 36V | 75V | 3.3V | 1.8V | - | - | 15A, 15A | 77 W | 1.88 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 125°C (With Derating) | 90% | - | - | Through Hole | Quarter Brick | - | - | - |
![]() |
SRSB-40U050DC DC CONVERTER 5V 40W Bel Fuse Inc. |
0 |
|
- |
xRSB-40U | Sixteenth Brick | Bulk | Obsolete | Isolated Module | 1 | 18V | 75V | 5V | - | - | - | 8A | 40 W | 1.5 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, SCP, UVLO | -40°C ~ 85°C (With Derating) | 87% | - | - | Surface Mount | Sixteenth Brick | - | - | - |
![]() |
UIS48T20033DC DC CONVERTER 3.3V 66W Bel Fuse Inc. |
0 |
|
![]() Tabla de datos |
- | Sixteenth Brick | Bulk | Active | Isolated Module | 1 | 18V | 75V | 3.3V | - | - | - | 20A | 66 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, UVLO | -40°C ~ 85°C (With Derating) | 90.5% | - | - | Through Hole | Sixteenth Brick | - | - | - |
![]() |
SQE48T20050-PGA0GDC DC CONVERTER 5V 100W Bel Fuse Inc. |
0 |
|
- |
SQE48 | Eighth Brick | Tray | Obsolete | Isolated Module | 1 | 36V | 75V | 5V | - | - | - | 20A | 100 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, UVLO | -40°C ~ 85°C (With Derating) | 91% | - | - | Through Hole | Eighth Brick | - | - | - |
![]() |
SQE48T20050-PGA0G-S2DC DC CONVERTER 5V 100W Bel Fuse Inc. |
0 |
|
- |
SQE48 | Eighth Brick | Tray | Obsolete | Isolated Module | 1 | 36V | 75V | 5V | - | - | - | 20A | 100 W | 2.25 kV | ITE (Commercial) | Remote On/Off, OCP, OTP, OVP, UVLO | -40°C ~ 85°C (With Derating) | 91% | - | - | Through Hole | Eighth Brick | - | - | - |